EFKA AB220A/320A FP220A/320A
66
Operator Level
Parameter Designation Unit max min Preset Ind.
019 -Pd 0 = Pedal in pos. –1 disabled in the seam. With pedal in 4 0 3 *) A/A/A/A
pos. –2 in the seam, only sewing foot lifting is
possible. (Function only if parameter 009 = 1)
1 = Pedal in pos. –1, sewing foot lifting disabled in the
seam.
2 = Pedal in pos. –2, thread trimming disabled.
(Function only if parameter 009 = 1)
3 = Pedal in pos. –1 and –2 enabled in the seam.
4 = Pedal in pos. –1 and –2 blocked in the seam.
(Function only if parameter 009 = 1)
020 kLM Clamp at the seam end On/Off 1 0 0 A/A/A/A
021 ckL Run-out stitches clamp at the start of the seam stitches 254 0 2 *) A/A/A/A
022 SPo 0 = Chain suction until the end of count c2 2 0 0 A/A/A/A
1 = Chain suction at the seam end until pedal in
pos. 0 (neutral)
2 = Chain suction until the drive is at standstill
and the switch-off delay (parameter 237) has
elapsed
023 AFL Automatic sewing foot lifting with pedal forward 1 0 1 A/A/A/A
at the seam end, if light barrier or stitch counting is On
0 = Automatic sewing foot Off
1 = Automatic sewing foot On
024 FSP Coupled thread tension release and sewing foot lift. 3 0 0 C/C/C/B
The function can be activated only with a thread
trimmer that depends on the angle.
(Modes 3, 13, 20, 22, 23, 25)
0 = No coupling
1 = Coupled thread tension release and sewing foot
at the seam end with thread trimmer off.
2 = Coupled thread tension release and sewing foot
in the seam and at the seam end with thread
trimmer off.
3 = Coupled thread tension release and sewing foot
always effective.
025 tFS Start counting (pa. 157) for thread tension release 1 0 1 A/A/A/A
at the start of the seam
0 = Start counting at the start of the seam
1 = Start counting when the light barrier is covered
030 rFw 0 = Bobbin thread monitor Off 6 0 0 A/A/A/A
1 = Bobbin thread monitor with stop
2 = Bobbin thread monitor without stop
3 = Bobbin thread monitor with stop and start
blockage after thread trimming
4 = As 1, but display of remaining stitches
5 = As 2, but display of remaining stitches
6 = As 3, but display of remaining stitches
031 cFw Number of stitches for bobbin thread monitor stitches 25500 ***) 0 0 A/A/A/A
035 UFw 0 = External bobbin thread monitor Off 2 0 0 F/F/F/E
1 = Bobbin thread monitor with stop after stitch
counting (prameter 036)
2 = Bobbin thread monitor without stop
036 cUF Number of stitches for Juki bobbin thread stitches 5000 **) 0 0 F/F/F/E
monitor
*) Depending on the selected mode. See table at the beginning of the List of Parameters!
**) When programming the 3-digit or 4-digit control parameter values (without control panel), the 2-digit or 3-digit
value displayed must be multiplied by 10.
***) When programming the 5-digit (max) parameter values on the control or control panel, the 3-digit value displayed
must be multiplied by 100.
Seitenansicht 65
1 2 ... 61 62 63 64 65 66 67 68 69 70 71 ... 87 88

Kommentare zu diesen Handbüchern

Keine Kommentare